| Usage |
|
Indoor/outdoor |
| Dimension |
|
Width
900 mm
Height 1810 mm
Length 2770 mm |
| Weight |
|
T100 P 2250-2750 kg (*)
T100 PH 2770-3100 kg (*)
|
Fuel
|
|
Natural gas (**) |
(*) Indoor / Outdoor
(**) Different fuel is availible on request (biogas, diesel, kerosene, methanol, LPC)
|
 |
|
|
| Voltage ouput |
|
400/230 V AC, 3 phases |
| Frequency output |
|
50 Hz (60 Hz) |
 |
|
|
| Pressure min/max |
|
0.02 / 1.0 bar(g) |
| Temperature min/max |
|
0 / 60 °C |
| Lower heating value |
|
38-50 MJ/kg |
 |
| Hot water installation (power & Heat) |
|
| Thermal output (hot water) |
|
155 kW (±5) @ 70-90 °C |
| Total efficiency |
|
77 % (±1) @ 70-90 °C |
| Min water inlet temperature |
|
50 °C |
| Max water outlet temperature |
|
150 °C |
| Max water pressure |
|
25 bar(g) |
| Exhaust gas temperature |
|
90 °C @ 70-90 °C |
 |
|
|
| Electrical output |
|
100 kW (±3) |
| Electrical efficiency |
|
33 % (±1) |
| Fuel consumption |
|
333 kW |
| Exhaust gas flow |
|
0.80 kg/s |
| Exhaust gas temperature |
|
270 °C |
| Noise level |
|
70 dBA @ 1 meter |
| NOx |
|
< 15 ppm/v = 32 mg/MJ fuel (*) (**) |
| CO |
|
< 15 ppm/v = 18 mg/MJ fuel (*) (**) |
(*) Volumetric exhaust gas emission @ 15% 02, 100 % load and 15 °C air inlet temperature
(**) Turbec T100 is fully certified by CARB (Californian Air Resource Board)
|
 |
|
|
|
Expected life time of main components
|
| Gas turbine engine |
|
> 60 000 hrs |
| Recuperator |
|
> 60 000 hrs |
| Combustor |
|
> 30 000 hrs |
| Preventive (scheduled) maintanance |
|
Interval / Outage |
| Recuperator |
|
6 000 / 2 hrs |
| Combustor |
  |
30 000 / 8 hrs |
 |
|
|